SUYASH CARBON SILICON ANALYSER DOES NOT NEED FREQUENT CALIBRATION. OPERATES FROM -20 °C to 55 °C.  
 
  • Very accurate , fast process using latest microprocessor. Analysis within 75 seconds.When used with Suyash Patented Supercups, give readings in 45 to 55 seconds.

  • 3 separate digital displays for %C.E. , %C, %Si.

  • Suitable for Grey Iron, S.G. Iron (Ductile Iron) and Malleable Iron.

  • User friendly. No special training essential.

  • Built-in Data storage capacity up to 96 records.

  • Self diagnosis for various Errors during the process.

  • Optional printer attachment for collective printed data.

  • Practically maintenance free.

  • Computer interfacing using serial port for transfer of readings to computer ( Optional ).
 
Carbon Silicon analyzer Models and specifications
 
MODEL 3
ONLINE
STEEL
Accuracy

CE

±

0.05

C

±

0.05

Si 

±

0.10

CE

±

0.05

C

±

0.05

Si 

±

0.10

Mild Steel C

 

±

 

0.02

Cast Iron CE

 

±

 

0.05

C

±

0.05

Si

±

0.10

Recommended Use
C.I/S.G/M.C.I
C.I/S.G/M.C.I
Steel C.I/S.G/M.C.I
Temp Measurements With Tips
Provided
Provided
Provided
Number Of Channels
3
3
3
Graphical PC Interface
---
Provided
---
Data Transfer to Computers
Provided
Provided
Provided
4" Jumbo Display
Optional
Optional
Optional
Processing Time
50  Sec
50  Sec
30 Sec for steel 2 to
50 Sec for
CI/SG/MCI
Printing
Parallel Port
From computer
Serial & Parallel Port
Operating Range
-20 to +55 °C
-20 to +55 °C
-20 to +55 °C
Voltage STD/ optional
200 to 260 V/ 110V
200 to 260 V/ 110 V
200 to 260 V/       110V
Frequency
50 / 60 Hz,     ± 2%
50 / 60 Hz,     ± 2%
50 / 60 Hz,     ± 2%
Display
25mm LED Hi Glow Type
25mm LED Hi Glow Type
25mm LED Hi Glow Type
Memory
96 Readings
96 Readings
96 Readings
Copyrights Suyash Solutions @ 2009